UNIPASS Troubleshooting Guide:

 

  1. UNIPASS® Was Not Permitted To Be Installed In C:Program Files Directory
  2. SafeNet Security Software Was Not Installed Properly
  3. USB Port Security Device Was Not Read Properly
  4. Operation Buttons Are Not Displayed In The Method Definition Window
  5. The Installation Support Files Cannot Be Installed In C: Drive
  6. Update License Data From License Key
  7. New Macro Commands In UNIPASS.IN
  8. UNIPASS.IN Was Not Created Before Running The UNIPASS® Solver
  9. Run UNIPASS® In A Read-Only Folder
  10. The Path Length To Run UNIPASS® Solver Is Longer Than 80 Characters
  11. UNIPASS® Education Version Can Only Run Example Problems Listed In Training Problem Reference Guide
  12. Missing Table of Contents in UNIPASS® HTML Output File
  13. Missing Operator * Between Two Parentheses or Between Constant and Random Variable in Function Definition Window
  14. Function Name Repeated in Function Definition Window
  15. Failure To Define Minimum Cut set in Function Definition Windows
  16. Variable Definition Window Crashes
  17. No Failure Domain in the Probability Analysis
  18. Improper Convergent Tolerance for g(x) = g_init in MPP Identification
  19. Curvature Fitting of SORM Is Not Available For Non-gradient MPPL Method
  20. Number of Sample Points Is Not Enough in Monte Carlo Simulation
  21. Maximum Number of g-function Calculations Is Less Than the Number of Sample Points in the Monte Carlo Simulation
  22. Maximum Number of g-function Calculations Is Less Than the Number of Sample Points in Directional Simulation
  23. The Maximum Number of g-function Calculations Is Less Than the Number of Sample Points In Sphere Based Importance Sampling Method
  24. Fitting Points May Be Out of Scope For g-function Calculation In Response Surface Method Based On User Defined Expansion Point
  25. The Number of Random Variables Is Limited To Be Between 3 and 16 In Response Surface Method
  26. Mean Value First-Order Second Moment Method only uses first two moments of random variables
  27. MV and AMV Use Full Distributions of Random Variables
  28. Parametric File Was Not Exited Before Running UNIPASS® Solver In Conjuction With External Softw
  29. Insufficient Space To Enter Enough Significant Value For Random Variables In Parametric File
  30. Verify The Results From External Software By Using VARS.SAV

Return to Top

11. UNIPASS® Education Version Can Only Run Example Problems Listed In Training Problem Reference Guide

Problems 1 through 15 listed in Training Problem Reference Guide can be solved with or without the License key (Education Version). All the results for these 15 problems are stored in the directory of C:\Program Files\UNIPASS\Examples\ClosedForm. However, if you are running UNIPASS without the license key, you will encounter the following restrictions:

  • UNIPASS may only be used to solve the problems listed in document
  • Some UNIPASS capabilities are disabled
  • The limit-state functions may not be changed or modified
  • The number and order of random variables may not be changed

The results of Problems 1 through 15, including the input and output, are listed in the C:\~\UNIPASS\Examples\ClosedForm directory which can be created by the distributed UNIPASS diskettes.

troubleshooting_sdmenu.png